Yunfan Medical Equipment Co., Ltd.

home products Others EB-5000 Hemorheology analyzer

EB-5000 Hemorheology analyzer

Detailed Product Description


 

Test Function

Testing project: whole blood, plasma, blood-fat, blood-sugar, thrombus, hematid, hemoblast , etc.

Testing parameters:

WBV (Whole blood viscosity)

High shearmpa.s)1201/s) 5.70 4.12--5.64

Middle shearmpa.s) 501/s) 6.85 5.32--6.99

Low Shearmpa.s) 20(1/s) 9.28 7.00--9.51
PV(Plasma viscosity)  1.48 1.20--1.73
HCT  (%) 45.4  42.52--48.44
ESRBlood sedimentation rate(mm/h)  21 0.00--20.00
WBRV High Shear 9.30  4.93--8.36

Middle shear 11.83  7.43--12.67

Low shearmpa.s) 17.18  13.41--22.53
ESRK  84.34 0.00--93.00

EAI (Erythrocyte aggregation) 1.63  1.24--2.30
RBCD 0.92  0.60--1.10

RBC rigidity  6.28  2.80--8.71


Erythrocytes electrophoresis 3.59 2.56--5.40
WBRV( whole blood relative viscosity) High Shear 3.85 2.38--4.71

Middle shear 4.63 3.07--5.83

Low shear 6.27 4.00--7.90
CHOL(mmol/l): 5.53 2.32--6.10
TG(mmol/l): 3.8 0.23--1.72

GLU(mmol/l): 5.33 4.00--6.00
Plasma fibrinogen

Platelet adhesion

erythrocyte deformability

Features

Bionics Principle: motivity &pressure sensor, quantitative assay.

Standardization measure:

The result is accord with ICSH(International Committee for Standardization in Hemato-logy) . to meet safety criterion operation requirements

The blood and plasma are measured continuously, ploting the non-Newton flow, performance curve of blood

Advantages:

39 sample seats on a open turnplate, directly sampling by primary tube

Automatic recognition of blood-coagulum

Prewarning interface of liquid waste and washing liquid automatically

Bar code identification technique:

No need to input the parameters on manual, the sample is identified automatically

Liquid interfaced probe:

automatic liquid interfaced detection and collision prevention function,no need to individually separate  plasma on manual

Quality Control of whole process,Washing liquid switch automatically .thimble double-needle emerging fountain washing mode,Specialized cleaning seats, exterior and interior side of sampling needle can be cleaned automatically

Pre-setting to mix well

mixing the sample automatically to avoid effect of the blood sedimentation

Software innovation

patientsdata can be measured and recorded simultaneously or separately

Network: connect to blood sedimentation,RIS, LAN to share Information

No need man to be on duty:

The whole process is automatic , the doctor doesn't need to set the sample position.

      

No wastage

long-life sensor detection without contacting, no machine wastage. Dynamic balancing testing function never block.

Data storage: memory capacity of 1,000,000 recent test results

Technical parameters:

Sample Volume : Whole Blood : 2.0ml ; Plasma: 0.8ml

Repetitive Deviation ::

Shearing ratio: 1s-1~200s-1


Whole Blood: High Shear Rates< 1.5% ; Low Shear Rates< 3%
Plasma< 1.5% 

Testing Time (including cleansing time):

Whole Blood : 60 Seconds /Pcs

Plasma : 30 Seconds /Pcs

Temperature control: 37±1

Power requirementAlternating current 220VA , 50 Hz±1Hz

Working condition: Temperature 1030, Humidity <80

Size 600mm*480mm*420mm

Weight20kg

EB-5000 Hemorheology analyzer EB-5000 Hemorheology analyzer

Send your message to this supplier
« Prev Product 1 2 3 4 5 6 7 ... Next Product »

Other Products from this Supplier

Company Info

Yunfan Medical Equipment Co., Ltd.
[China (Mainland)]
[Verified Member]

City: Chongqing
Province/State: Chongqing
Country/Region : China (Mainland)

Business Type:Manufacturer, Trading Company

View Contact Details

Email this page Bookmark this page Print this Page